Physical
Size:
10.0 x 5.7 x 5.7in. (255 x 145 x 145mm)
Weight:
5.5lbs. (2.5Kgs) with Li-ion cells.
Case:
Injection molded plastic. Waterproof(IP67)
Display: High brightness color TFT LCD display. Display area
4.05” x 3.03” (103 x 77mm) 320 x 240 pixels. A-Scan area 255 x 200
pixels.
Note: Optional monochrome LCD for improved visibility
in high ambient light. Adjustable contrast and switchable
backlight.
Transducer Connectors: available with
BNC or “00” LEMO connectors.
Temperature:
Operating –10 to +55°C. 14 to 131°F –20 to +70°C. –4 to 158°F (survivable)
LCD Version: 0 to +50°C or 32 to 122°F (survivable).
Storage: –40 to +75°C. –40 to 167°F
Environmental: Meets IP65 requirements.
Ultrasonic Specifications
System Linearity: Vertical = 1% Full Screen Height (FSH) Amplifier
Accuracy ±0.1%dB. Horizontal ±0.4% Full Screen Width (FSW).
Pulser: 444 Fixed square wave pulse linked to
frequency selection. Tx width 40ns min, 250ns max. 544
Variable square wave pulser with 2 voltage settings:
200V, 20-500ns and 0-500ns and 400V, 100-500ns. Pulse
width adjustable in 1 and 10ns steps.
Delay: 444 Calibrated delay from 0-200
in. in 0.002in. steps (0 to 5000mm in .05mm
steps) at steel velocity. 544 Calibrated delay
from 0-400in. in 0.05in steps (0-10000mm in
1mm steps) at steel velocity.
Gain: 0 to 110dB. Adjustable in 0.5,
2, 6, 14 and 20dB steps. Direct access to gain
control at all times.
Damping: 544 Selectable between 50,
100,180 & 400 ohms.
P.R.F.: Adjustable to 35, 63, 150, 250,
500 & 1000Hz maximum.
Frequency Range: 444 4 Narrow Bands
centered at 1MHz, 2.25MHz, 5MHz, & 10MHz.
Wide Band 1.5MHz to 15MHz (-6dB). 544 5 Narrow
Bands centered at 1MHz, 2MHz, 5MHz, 10 MHz, & 15MHz.
Broad Band at 0.3-22MHz(-6dB).
|
Memory
Thickness Logging: Storage for 2000
thickness readings configured into Block/Location/Number.
Calibration settings stored with each Block.
Maximum number of Blocks is 14. Unlimited Location/Number
values, maximum combination of 2000 readings.
Readings may be reviewed, edited and printed
as required.
Panel Memory: 20 storage locations
for retaining calibrations.
A-Scan Memory: Maximum of 100 waveforms
stored with complete panel settings. Waveforms
may be recalled on display, printed or transferred
via RS232 serial port.
Notes: Alphanumeric labeling for panel
and A-Log allows the user to enter Notes for
storage with A-scans.
Measuring
Units: English (in), Metric (mm), or
Time (µs).
Test Modes: Pulse-echo and transmit/receive.
Measurement Modes:
(444 5 modes, 544 6 modes)
Mode 1 Signal Monitor.
Mode 2 Depth and amplitude of first signal
in gate.
Mode 3 Echo-to-echo distance measurement.
Mode 4 444 / Mode 5 544 Trigonometric display of beam path, surface
distance and depth of indication.
Mode 5 444 / Mode 6 544 T-Min mode for holding minimum thickness
reading. Resolution to 0.001in. (0.01mm) for distance measurement,
or 1%FSH for amplitude measurement. Large display of measurement
at top of A-Scan display. Measurement mode selectable between peak
and flank.
Note: All measurement functions also available
in unrectified RF mode.
Test Range: 444 0.2-400in. (5 to 10000mm)
at steel velocity. 544 0.05-800in. (1mm to
20000mm) at steel velocity. Variable in 1,2,5
sequence, or continuously in 0.05in. (1mm)
Increments. Also from 1 to 5000 (µs).
Velocity: 444 0.0393 to 0.3937 in./micro-second
(1000m/s to 9999m/s) 544 .0101 to .6299 in./microsecond
(256m/s to 16000m/s) continuously variable.
Probe Zero: 0 to 999.999 µs, continuously
variable.
Warranty
2 year limited
|
Features
Peak Memory: For echodynamic pattern
determination.
Gate Monitor: Two fully independent
gates for echo monitoring and thickness measure-ment.
Start and width adjustable over full range
of unit, amplitude variable from 0 to 100%
FSH. Bar presentation. Positive or negative
triggering for each gate with visual and audible
alarms.
Gate Expansion: Expands range
to width of Gate 1.
Display Freeze: For capturing
current A-scan image.
DAC: DAC curves may be entered
and digitally drawn on the display.
Reference, –6dB, –12dB, –14dB curves
may be selected. DAC curve selected
acts as gate for alarm outputs and
height measurement in DAC +dB. DAC
parameters stored with Panel Memory.
Curves comply with ASME and JIS Codes.
TCG: Time Corrected Gain, also known
as Swept Gain. 40dB dynamic range greater than
30dB per microsecond and up to 10 points may
be used, setting all signals initially to 80%
Full Screen Height.
Reject: 444 50% suppressive reject.
LED warning when selected. 544 80% linear reject.
LED warning when selected.
AWS–DGS: Built in Software for evaluation
of defect indications in accordance with AWS
standards or the AVG/DGS Method.
Auto_Cal: Provides Automatic calibration
from two echoes.
Rectification: Full wave, positive or
negative half wave and unrectified RF.
Help Key: On screen context-sensitive
help.
Power Source:
Power: Lithium Ion battery pack 14.4V,
5.0 Amp hrs, 8 hours battery life fully charged.
15hrs. LCD battery life. Two hour charge time.
Low battery indicator.
Charger: Universal line power input
110 or 230 volts A.C.
Outputs
Data: Full bi-directional RS232 serial
interface to transfer parameters, thickness
readings and waveform memories.
Analog: Proportional outputs programmable
to distance or amplitude of signal. Unrectified
RF signal 80mV peak to peak. Synchronisation
output for start of scan. Gate trigger output
on relay contact.
Video: Composite video, full PAL, or
NTSC compatibility. Update rate: 60Hz (NTSC